Image of Agilent 6560 Ion Mobility Q-TOF LC/MS
Agilent 6560 Ion Mobility Q-TOF LC/MS image 0Agilent 6560 Ion Mobility Q-TOF LC/MS image 1Agilent 6560 Ion Mobility Q-TOF LC/MS image 2Agilent 6560 Ion Mobility Q-TOF LC/MS image 3Agilent 6560 Ion Mobility Q-TOF LC/MS image 4Agilent 6560 Ion Mobility Q-TOF LC/MS image 5Agilent 6560 Ion Mobility Q-TOF LC/MS image 6Agilent 6560 Ion Mobility Q-TOF LC/MS image 7Agilent 6560 Ion Mobility Q-TOF LC/MS image 8Agilent 6560 Ion Mobility Q-TOF LC/MS image 9Agilent 6560 Ion Mobility Q-TOF LC/MS image 10

Agilent 6560 Ion Mobility Q-TOF LC/MS

Used Agilent 6560 Ion Mobility Q-TOF LC/MS for sale. SSLLC offers a wide selection of used Mass Spectrometers for your Used Lab Equipment needs.


Product Code: 338932

Manufacturer: Agilent Technologies

Model: G6560A

Serial: SG1536C001

Location: Woonsocket, RI

Request a QuoteSell Similar



  • Product Details
  • Documents

The Agilent 6560C ion mobility Q-TOF LC/MS system delivers unrivaled separation and selectivity by combining chromatography, ion mobility, and mass spectrometry. The 6560C Q-TOF LC/MS can even uncover structural information that cannot be seen with traditional LC/MS systems, including separation of in-class isomers via high-resolution demultiplexing (HRdm).

 

The system features innovative electrodynamic ion funnel technology to dramatically improve sensitivity while maintaining an attractive low field drift tube design. This allows you to directly measure accurate collision cross sections (CCS) and preserve labile targets. Whether you are looking to create a more comprehensive profile of metabolomics samples, characterize complex polymeric mixtures, or understand structural changes in biomolecules, ion mobility mass spectrometry provides access to new information.

 

Features

  • First-principle based collision cross-section measurement and accuracy without standards.
  • Utmost separation capacity, combining UHPLC, ion mobility, and high resolution mass spectrometry.
  • Better separation of complex isobaric classes such as lipids and glycans.
  • In-depth characterization of structural conformations and isomeric compounds.
  • Conservation of structural fidelity of molecules in the gas phase using the low-energy drift tube design.
  • Multiplexing for substantially increased sensitivity and dynamic range, with enhancement of one order of magnitude.
  • Ion mobility resolution of up to 200 in full spectra can be achieved via postprocessing with the Agilent high resolution demultiplexing ( HRdm 2.0) software.
  • Collision-induced unfolding (CIU) for quantitative structural analysis of proteins includes in-source activation for induced fragmentation of molecules.
  • Up to 5 Hz acquisition rate can be used without compromising resolution for UHPLC compatibility.
  • Utilizes Agilent VacShield for vent-free capillary removal.

 

Used Agilent 6560 Ion Mobility Q-TOF LC/MS for sale. SSLLC offers a wide selection of used Mass Spectrometers for your Used Lab Equipment needs.

 

If you are interested in the Agilent 6560 Ion Mobility Q-TOF LC/MS be sure to check out our other available Mass Spectrometers by Agilent Technologies. Request a quote to receive more information on this Agilent 6560 Ion Mobility Q-TOF LC/MS. Have a Agilent 6560 Ion Mobility Q-TOF LC/MS to sell? Fill out this Sell Equipment form.


System Includes Agilent 1260 Infinity HPLC With The Following Components
1260 Quat Pump (S/N DEAB715112)
1260 TCC (S/N DEACN40478)
1260 ALS (S/N DEAAC38065)
1290 Thermostat (S/N DEBAK26483)
Peak NM32LA Nitrogen Generator (Electrical: 230V, 50/60Hz, 7 Amps)

Association of Machinery and Equipment Appraisers
LabOps Unite
Mass Bio
Machinery Dealers National Association
NC Life Sciences Organization
NAA Auctioneers